Furnace Not Turning On: Causes, Troubleshooting and Repair in Louisiana

A furnace that will not turn on most often traces back to something basic: a thermostat setting or dead batteries, a tripped breaker, a furnace power switch left off, or an access panel that is not fully closed. Ignition, flame sensor, pressure switch, and safety shutdown faults are also common, but those need a technician. If you smell gas or a carbon monoxide alarm sounds, leave first and call 911.

Key takeaways

  • If you smell rotten eggs or a CO alarm sounds, stop troubleshooting. Leave on foot, avoid light switches and phones inside, and call 911 from somewhere else.
  • Four checks solve most no-start calls that homeowners can fix themselves: thermostat mode and batteries, the furnace power switch, the breaker, and the blower access door.
  • A furnace that fires and then quits within a few minutes is usually being stopped by a safety control that is doing its job. The question is what tripped it, not how to override it.
  • Reset once. If it fails again, or the breaker trips a second time, stop there. Repeated resets can turn a contained fault into a fire, gas, or electrical hazard.
  • Acadiana’s heating season is short, so a furnace can sit unused for eight or nine months. Most of what fails in December was already failing in March, unnoticed.

A cold front pushes through overnight, the house drops into the fifties, and the furnace does nothing. No hum, no click, no warm air. It is an unsettling moment, partly because a gas furnace is the one piece of home equipment most people know they should not poke at.

This guide walks through the problem in the order a technician would: safety first, then the handful of checks that are genuinely safe to do yourself, then what the symptom pattern suggests, and where the line sits between a homeowner fix and a service call. By the end, you should know whether you are looking at a dead thermostat battery or something that needs a licensed technician on site.

Why Is My Furnace Not Turning On?

A furnace needs four things to start a heating cycle: a call for heat from the thermostat, electrical power, fuel, and a set of safety controls that all report normal. Break any one of those and the furnace stays off. That is why the causes range from a $4 battery to a failed control board, and why the symptom alone does not identify the part.

Before anything else, rule out the two situations that are not troubleshooting problems. If you smell rotten eggs anywhere in the house, or if a carbon monoxide alarm is sounding, leave the building and call 911 from outside. Do not look for the source, do not flip switches, and do not check the furnace. Those two signs outrank every other instruction on this page.

If there is no gas odor and no CO alarm, the situation is almost certainly a comfort problem rather than a safety emergency, and it is reasonable to work through the basic checks below. Louisiana’s mild winters give you a little room here. Lafayette’s January normals run about 62°F by day and 44°F overnight, according to the National Weather Service, so a house rarely gets dangerously cold while you wait for a morning appointment. That same mild climate is part of why furnaces fail at startup: the system may have sat untouched since the last cold snap, and dust, corrosion, and clogged drains accumulate quietly during nine months of cooling season.

Furnace Safety Warning Signs You Should Never Ignore

Most no-start furnaces are simply off. A small number are off because something has gone wrong with combustion or venting, and those cases announce themselves. Learn the three signals below,w and you will know immediately which situation you are in.

What to Do if You Smell Gas

Natural gas has no odor of its own. Utilities add a sulfur compound so a leak smells like rotten eggs, which is the one warning sign you get. A hissing or blowing sound near the furnace or gas line counts too.

If you smell it, federal pipeline safety guidance is specific about what not to do. Do not light a match or a lighter. Do not turn light switches, lamps, or garage door openers on or off. Do not use a phone inside the house, cordless or cell. Do not start a vehicle in an attached garage. Each of these can produce a spark.

What you should do is leave on foot, take everyone with you, and call 911 and your gas utility from a neighbor’s house or from the street, well away from the building. Leave the door open behind you if that is easy to do. Do not go back inside to grab anything, and do not re-enter until the fire department or the utility says the building is clear. Reporting a suspected leak is free, and utilities would far rather check a false alarm than miss a real one.

Carbon Monoxide Warning Signs and Precautions

Carbon monoxide is produced when fuel burns incompletely. It has no color, no smell, and no taste, so a working alarm is the only reliable way to detect it. The Consumer Product Safety Commission recommends a CO alarm on every level of the home and outside each sleeping area, and its guidance on a sounding alarm is blunt: never ignore it, get outside immediately, and call 911.

CO poisoning can feel like the flu, usually without a fever. Headache, dizziness, nausea, weakness,s and confusion are the common symptoms, and a pattern worth paying attention to is when several people in the house feel unwell at the same time, or when symptoms improve after everyone has been outside for a while. Pets acting sick alongside people is another clue.

Some visible signs around a gas furnace also warrant a professional inspection even without an alarm: soot or dark staining around the furnace cabinet or vent connections, a burner flame that burns yellow or orange instead of crisp blue, excessive moisture on windows near the furnace, or a vent pipe that has come loose. None of these prove a problem on their own, but all of them are reasons to have combustion and venting checked rather than to keep restarting the unit.

When to Stop Troubleshooting and Seek Emergency Help

Stop and get out, then call for help, if any of the following are present:

  • A gas odor anywhere in the home, however faint, or a hissing sound near the furnace or gas piping
  • A carbon monoxide alarm sounding, or several people in the house feeling sick at once
  • Smoke, a burning smell, scorch marks, melted wiring, or visible sparking at the furnace or electrical panel
  • Flames visible anywhere outside the burner compartment
  • Water pooling around a furnace that is also showing electrical symptoms

For smoke, burning odors, or arcing, call 911. For a gas odor or a CO alarm, call 911 and your gas utility from outside. After emergency responders have cleared the home, an HVAC technician can diagnose what caused it. Those two steps happen in that order, not at the same time.

How to Troubleshoot a Furnace That Won’t Turn On

These checks are safe because none of them require tools, opening sealed components, or touching anything electrical beyond a switch and a breaker. Work through them in order. The sequence matters, since each step rules out a category of cause before you spend time on the next one.

Check Thermostat Settings and Batteries

Start here, because the thermostat is the only part of the system most people touch, and it fails in quiet ways.

Confirm the thermostat is set to Heat, not Cool, Off, or Auto-changeover sitting in a cooling band. Then raise the setpoint at least five degrees above the current room temperature. A thermostat set to 68°F in a 69°F house is behaving correctly by doing nothing.

If the display is blank, dim, or frozen, replace the batteries even if they were changed recently. A battery-powered thermostat that is low on charge can hold a display while losing the power it needs to close the heating circuit. On a smart or Wi-Fi thermostat, check that the screen is actually responding and not stuck mid-update, and that a schedule or an away setting is not holding the temperature down. Fan set to On instead of Auto is another common one: it blows unheated air continuously, which feels like a furnace running cold rather than a furnace that will not start.

If you replaced the thermostat recently, the wiring is worth mentioning to a technician. Many newer thermostats need a common wire that older systems were not wired for.

Check the Power Switch, Circuit Breaker, and Access Door

Furnaces have a dedicated power switch that looks exactly like a light switch, usually on or near the furnace cabinet, on a wall nearby, or at the top of the attic stairs. It gets flipped off during painting, cleaning, or attic storage and then forgotten. Check it before anything else electrical.

At the electrical panel, look for a breaker labeled furnace, heat, or air handler that has tripped to the middle position. Switch it fully off, then back on. Do this once. If it trips again, leave it off and call a technician, because a breaker that keeps tripping is reporting a fault, not malfunctioning.

Then check the blower compartment access door. Furnaces have a door safety switch that cuts power whenever the panel is removed or not seated properly, which is a deliberate protection against running the blower with the cabinet open. After a filter change, a panel that is slightly off its track will keep the furnace completely dead. Push the door firmly into position and listen for the switch.

One more item specific to gas furnaces: confirm the gas supply is actually on. If other gas appliances in the house, such as a water heater, stove, or dryer, have also stopped working, the issue is upstream of the furnace and belongs to the gas utility.

Check the Air Filter, Vents, Condensate Drain, and Vent Pipes

Pull the filter and hold it up to a light. If you cannot see light through it, it is restricting airflow enough to matter. A severely clogged filter can cause the heat exchanger to overheat, which trips a limit switch and shuts the furnace down, sometimes before the blower ever reaches full speed. ENERGY STAR recommends checking the filter monthly and replacing it at least every three months.

Walk the house and confirm supply registers and return grilles are open and unblocked. Furniture pushed against a return, or registers closed off in unused rooms over the summer, reduces airflow in the same way a dirty filter does.

Condensate is worth a closer look in this climate. High-efficiency condensing furnaces produce water as a byproduct of combustion, and in most Louisiana homes that drain line is shared with the air conditioning coil that has been running all summer. A line fouled with algae or sludge backs up, a float switch senses the standing water, and the furnace is locked out before it can start. You can look for standing water in the drain pan or a visibly blocked drain line. Clearing a stubborn blockage and resetting the switch is work for a technician.

Outside, check that the PVC intake and exhaust pipes on a high-efficiency furnace are clear. Wasp nests, mud dauber nests, and debris are a recurring cause of blocked venting in South Louisiana, and a blocked vent trips the pressure switch so the furnace never ignites. Look at the terminations from the outside only. Do not disassemble or reach into vent piping.

Read the Diagnostic LED Error Codes

Most furnaces built in the last two decades have a small viewing window on the front panel with an LED that flashes a diagnostic pattern. It is the single most useful piece of information you can collect before calling anyone.

Watch the light and count the pattern: a steady green light, a slow flash, a rapid flash, or a repeating group such as three short blinks followed by a pause. Write down exactly what you see. The legend that translates the pattern is usually printed on the inside of the access panel or on a label on the cabinet, and codes are not standardized between manufacturers, so three flashes on one brand means something different on another.

You do not need to interpret the code yourself. Reading it over the phone lets a technician arrive knowing whether to expect an ignition fault, a pressure switch issue, or a limit trip, and whether the likely part is on the truck. If the light is off entirely, that points back to a power problem: the switch, the breaker, or the access door.

What Does It Mean When Your Furnace Has Power but Won’t Start?

When the thermostat has power, and the breaker is on but nothing happens, the sounds the furnace makes, or does not make, narrow the field considerably. None of this identifies a failed part, because that takes measurement, but it tells you how far along the startup sequence the furnace got before it stopped.

What you observeWhat it tends to point towardSafe to keep checking?
Nothing at all, no hum or clickPower, controls, or a safety lockout before the sequence beginsYes, recheck switch, breaker, door
Thermostat clicks, furnace does nothingThe call for heat is not reaching the furnace, or is not being acted onYes, but likely a service call
Clicking or sparking, no flameIgnition, gas delivery, or a safety control blocking ignitionStop after one reset attempt
Fires up, quits within minutesA safety control shutting the furnace down on purposeStop, do not keep restarting

Furnace Is Completely Silent

No hum from the control board, no inducer motor spinning up, no click from the gas valve. Complete silence almost always means the furnace is not receiving power or is not being told to run. Work back through the power switch, the breaker, and the access door, and check the thermostat display.

If power is confirmed and the unit is still silent, the fault is likely in a control component: a blown low-voltage fuse on the control board, a failed transformer, or the board itself. Those are measured with a meter, not guessed at.

Thermostat Clicks but the Furnace Doesn’t Turn On

That click is the thermostat closing the heating circuit. The thermostat is doing its part; the message is not getting through or not being acted on. Broken or loose low-voltage wiring between the thermostat and the furnace, a wire knocked loose during a recent thermostat swap, a failed transformer, or a control board that is not responding can all produce this.

In a dual-fuel or heat pump system, this pattern has an extra wrinkle. Many Acadiana homes heat with a heat pump and call on gas or electric backup only in colder weather, so what looks like a furnace that will not start may be a system correctly running in a mode you did not expect. If the air from the registers is lukewarm rather than hot, that is worth mentioning when you call, since it changes the diagnostic path entirely.

Furnace Clicks but the Burners Won’t Ignite

You hear the sequence begin, maybe a repeated clicking or a brief glow, and then it stops without heat. The furnace is trying and failing to establish or confirm a flame. Common contributors are a failed hot surface igniter, a dirty flame sensor, a pressure switch that is not closing, or an interruption in gas supply.

Many furnaces will attempt ignition a set number of times, then lock out for an hour before retrying automatically. That lockout is designed behavior, not a breakdown. It also means a unit that appears to fix itself an hour later has not fixed anything.

Furnace Starts but Shuts Off Immediately

The furnace lights, runs briefly, and shuts down, sometimes repeatedly. This is short cycling, and in nearly every case a safety control is ending the cycle deliberately. A limit switch responding to overheating from restricted airflow, a flame sensor that cannot confirm the flame it is looking at, a pressure switch reacting to a venting problem, or a condensate float switch reacting to a backed-up drain are the usual culprits.

If the shutdown follows a clogged filter, replacing the filter and letting the unit cool may clear it. Otherwise, the safety control is reporting a real condition, and the useful question is what it detected. Repeated restarts strain the igniter and the blower motor without addressing it.

Most Common Causes of a Furnace Not Turning On

How the Startup Sequence Works (and Where It Fails)

A modern gas furnace runs a fixed sequence every time it heats, and each step has to confirm before the next one is allowed. Understanding the order explains why so many different faults produce the same silence.

  1. The thermostat calls for heat and closes a low-voltage circuit to the furnace control board.
  2. The board checks its safety circuit. Limit switches, the condensate float switch, and the door switch must all read normal.
  3. The draft inducer motor starts, clearing the heat exchanger and establishing venting airflow.
  4. The pressure switch senses that airflow and closes, proving the vent is clear.
  5. The igniter energizes, glowing hot or producing a spark.
  6. The gas valve opens and the burners light.
  7. The flame sensor confirms a flame within a few seconds. Without confirmation, the gas valve closes immediately.
  8. The blower starts after a short delay and pushes warm air into the house.

A failure at step two or three leaves you with near silence. A failure at step four or five gives you clicking without heat. A failure at step seven gives you a furnace that lights and dies within seconds. That is why the sounds from the earlier section are diagnostic.

Thermostat or Electrical Control Problems

The thermostat side covers dead batteries, a lost schedule after a power outage, miswiring after a replacement, and the low-voltage wiring running back to the furnace. On the furnace side, a blown control board fuse, a failed low-voltage transformer,r or a faulty control board produces the same outcome from a different direction.

An important distinction: a tripped breaker is a symptom, not a diagnosis. A furnace breaker that trips once may have responded to a momentary surge. One that trips every time it is reset is reporting a short, a ground fault, or a motor drawing too much current, and resetting it repeatedly is both unsafe and uninformative.

Dirty Air Filter and Overheating Safety Shutdowns

A restricted filter starves the furnace of return air. Less air across the heat exchanger means heat builds up faster than it can be carried away, and the high limit switch opens to prevent the exchanger from being damaged. Depending on how severe the restriction is, that can happen minutes into a cycle or almost immediately.

This is also the failure most often misread as a dead furnace. A unit that has been tripping on high limit all season may eventually refuse to start at all. Replacing the filter is worth doing before you call, but if the furnace has been short cycling for a while, the limit switch and the heat exchanger deserve a look, because repeated overheating is not harmless.

Faulty Igniter or Extinguished Pilot Light

Furnaces made in roughly the last 30 years use a hot surface igniter, a brittle ceramic element that glows orange to light the burners. Igniters are consumable. They crack, develop hairline fractures, and fail, often without warning, and a cracked igniter can look intact. The usual sign is a furnace that runs through its sequence and never produces flame.

Older furnaces may use a standing pilot light. If yours has one and it is out, the owner’s manual will give the relighting procedure specific to that model. Follow it exactly, and if the pilot will not stay lit, stop. A pilot that goes out repeatedly often indicates a failing thermocouple or a draft or venting problem, and those need a technician rather than another attempt.

Dirty Flame Sensor or Faulty Pressure Switch

The flame sensor is a thin metal rod that sits in the burner flame and confirms it is actually burning. It works by detecting a very small electrical current through the flame, which means a film of oxide or residue on the rod is enough to break the signal. The furnace lights, fails to confirm the flame, and shuts the gas valve within seconds as a safety measure. The classic pattern is a furnace that ignites and dies after two or three seconds, over and over.

Flame sensors are a routine maintenance item for a technician and a common cause of mid-season no-heat calls, particularly on systems that sat unused through a long cooling season.

The pressure switch proves the draft inducer is moving air and the vent is clear before gas is allowed to flow. It can fail electrically, but it also reports genuine problems: a blocked exhaust termination, a disconnected hose, water in the vent piping, or a failing inducer motor. Because the switch is a safety device, the fix is to find what it is detecting, never to bypass it.

Gas Supply or Gas Valve Problems

The simplest version is no gas: a closed shutoff valve, an interrupted utility supply, or an empty propane tank. Check whether other gas appliances in the home still work. If the stove and water heater are also out, the problem is upstream of the furnace.

If gas is present elsewhere but the furnace gets none, the gas valve, its wiring, or the control signal driving it may be at fault. Gas valve testing, replacement,t and any adjustment to gas pressure is licensed work. It is not a homeowner repair under any circumstances.

Blower Motor or Control Board Failure

A failed blower motor or a bad capacitor can prevent a heating cycle from completing, and on some systems the furnace will not attempt ignition at all if it cannot confirm the blower. Symptoms include a humming sound with no air movement, a burning smell from an overheating motor, or a breaker that trips when the blower is called.

The control board coordinates the whole sequence. When it fails, the behavior can look like almost anything: no response, partial sequences, intermittent operation that comes and goes. Boards are also sometimes replaced unnecessarily, which is a good reason to expect a technician to test the circuit rather than substitute parts.

Condensate Drain Blockages and Safety Switch Problems

High-efficiency condensing furnaces, generally those rated 90% AFUE and above, extract so much heat from the exhaust that water condenses out of it. That water drains away through a trap and a drain line, and most installations route it into the same drain the air conditioning coil uses.

In this climate, that line has been carrying condensate all summer, which is exactly how it collects algae and sludge. When it blocks, water backs up into the pan, and a float switch opens the circuit, shutting the furnace down before it can start. It is a safety control preventing water damage, and it is a frequent cause of a heating system refusing to run for a reason that has nothing to do with heating.

The tell is standing water in the secondary drain pan or around the unit. Clearing the line properly, flushing the trap, and resetting the switch is service work, and it is one of the items a maintenance visit is meant to catch before it strands you.

Is It Safe to Reset a Furnace That Won’t Turn On?

A single reset is reasonable. A furnace can lock out after a power flicker, a brief gas interruption,n or a one-time ignition failure, and clearing that lockout lets it try again. The risk is not in the first reset. It is in treating the reset as the repair.

How to Safely Reset a Furnace (Per Manufacturer Instructions)

Check your owner’s manual first, because procedures differ by model, and some furnaces have a dedicated reset button while others do not.

The general approach is to set the thermostat to Off, then cut power at the furnace switch or the breaker. Wait a full minute so the control board clears. Restore power, confirm the access panel is properly seated, and set the thermostat back to Heat with the setpoint above room temperature. Then wait. A normal startup sequence takes a few minutes, and the blower is the last thing to engage, so warm air at the registers is not immediate.

If the furnace ignited but locked out, give it time. Many units enter a one-hour lockout after failed ignition attempts and will retry automatically without any intervention.

Two cautions. Do not hold or repeatedly press a reset button, and do not reset a furnace that has any sign of a gas odor, soot, water intrusion, or burning smell. In those cases,s the lockout is the furnace protecting you.

Why You Should Never Repeatedly Reset a Furnace

Every reset clears the evidence without clearing the cause. A furnace that locks out is almost always responding to a safety control that detected something real: overheating, a flame that could not be confirmed, a vent that is not drawing, water where it should not be.

Forcing it through that cycle again and again carries real consequences. Unburned gas can accumulate in the combustion chamber across repeated failed ignition attempts. Repeated overheating stresses the heat exchanger, which is the component separating combustion gases from the air you breathe. Igniters and blower motors wear out faster under repeated start attempts, turning a modest repair into a larger one.

The practical rule: reset once. If the furnace fails again, you have learned what you needed to know, which is that the fault is persistent and needs to be measured rather than restarted.

When to Call a Professional for Furnace Repair in Louisiana

The checks earlier in this article cover what can be done safely without tools. Past that point, diagnosis depends on measuring voltage, gas pressure, airflow,w and flame signal, which is licensed work for good reason. Here is where the line falls in practice.

Still Won’t Start After Basic Troubleshooting

If the thermostat is set correctly with fresh batteries, the power switch is on, the breaker is on, the access panel is seated, the filter is clean, and the furnace still does nothing, you have ruled out the homeowner-fixable causes. What remains sits inside the cabinet.

Circuit Breaker Trips Repeatedly

One trip can be incidental. A second trip is the system telling you something is wrong with the electrical load, and the most likely candidates include a shorted wire, a failing blower motor, or a ground fault. Leave the breaker off and call. Repeatedly resetting a breaker that keeps tripping risks overheating wiring and starting a fire.

Ignition Failures or Error Codes Keep Returning

A furnace that lights and dies, clicks without igniting, or throws the same LED code after a reset has a persistent fault. The same applies to a unit that works for a day and then quits again. Intermittent faults are harder to find, not less serious, and the code history stored on the control board is useful to whoever works on it.

Worth noting: if your system shuts down on the coldest nights of the year and runs fine otherwise, that pattern is a clue, not a coincidence. Marginal pressure switches, borderline gas pressure, and backup heat staging all tend to reveal themselves under load.

What a Technician Will Check (Electrical, Gas, Ignition, Airflow)

A furnace diagnostic generally covers four areas: electrical supply and control voltage, including the transformer, board fuse, and safety circuit; gas supply and valve operation, with gas pressure measured rather than estimated; the ignition system, meaning igniter resistance and the microamp signal from the flame sensor; and airflow and venting, including static pressure, the limit circuit, the inducer,r and the condensate drain.

Stored error codes usually get read first, since they point to where in the startup sequence the furnace is failing. If a heat exchanger is suspect, expect an inspection of it as well, because a cracked exchanger is a combustion safety issue rather than a comfort one.

Fontenot’s Air Conditioning & Heating handles heating repair and service across Acadiana, including Lafayette, Broussard and Youngsville, and services all brands of HVAC equipment. Appointments are available seven days a week from 7 a.m. to 8 p.m., and emergency service is offered seven days a week for situations that cannot wait.

How to Prevent Furnace Startup Problems

Replace Filters and Maintain Airflow

Airflow restriction sits behind a large share of overheating shutdowns, and it is the one failure path almost entirely within your control. ENERGY STAR recommends checking the filter monthly, especially during heavy heating and cooling months, and replacing it at least every three months. Homes with pets, heavy dust, or allergy concerns often need a change closer to every 30 to 60 days.

Two details that matter more than filter brand. First, fit: a filter that leaves gaps around the frame lets air bypass the media entirely, which defeats the point. Second, airflow design: a very high-MERV filter in a system that was not set up for it can restrict airflow enough to cause the problem you were trying to avoid. If you want better filtration, ask what your system can handle rather than buying by rating alone.

Beyond the filter, keep supply registers and return grilles clear of furniture and rugs, and resist closing vents in unused rooms. Closing registers does not save meaningful energy on most residential systems, and it raises static pressure across the equipment.

Schedule Furnace Maintenance Before Winter

The Acadiana heating season is short enough that a furnace may go eight or nine months without running. That idle stretch is precisely why so many systems fail on the first genuinely cold night: dust settles on burners, the flame sensor accumulates residue, the shared condensate line fouls through the cooling season, and insects nest in vent terminations. None of it announces itself until the furnace is asked to work.

A pre-season visit targets those failure points directly: cleaning the flame sensor and burners, checking igniter condition, testing safety controls including the limit and pressure switches, inspecting venting and the condensate drain, verifying gas pressure and combustion, and confirming airflow. It is far easier to find a cracked igniter in October than during the first cold front.

If your furnace has been slow to start, cycling oddly,y or making unfamiliar noises, that is the signal to schedule rather than wait. Fontenot’s furnace services cover pre-season inspections and repairs, and the company’s Energy Savings Plan includes two visits a year to review, clean, test, and maintain the system.

Conclusion

A furnace that will not turn on is usually stopped by one of three things: it is not getting a proper call for heat, it is not getting power or fuel, or a safety control is deliberately holding it off. The first two you can often sort out yourself in ten minutes with the thermostat, the power switch, the breaker, the access door,r and the filter. The third is where troubleshooting ends, because a safety control that trips is reporting a condition that has to be measured before it can be fixed.

Two things are worth carrying away. Gas odor or a sounding CO alarm means leave the building and call 911 before anything else. And reset once, never repeatedly, because each restart clears the evidence while leaving the cause in place.

If your furnace still will not start after the basic checks, if the breaker keeps tripping, or if the same error code keeps returning, it is time for a diagnostic visit. Fontenot’s Air Conditioning & Heating has served homes and small businesses across Acadiana since 2007 and provides heating and furnace repair in Lafayette, Broussard, Youngsville, le and the surrounding communities. Call (337) 789-6070 to schedule, seven days a week from 7 a.m. to 8 p.m. If you noted the LED flash pattern, mention it when you call, since it gives the technician a head start on the diagnosis.